Safety Relays and Categories in a Control Cabinet
Safety categories describe the architecture of a circuit, not the quality of a component. Category 3 with a single safety relay is not category 3 with duplicated contactors and monitored feedback, even though both are sold as "category 3 compliant".
What the risk assessment decides
The required performance level comes from the risk assessment: severity, frequency, possibility of avoidance. In practice, an emergency stop on a machine with a guarded danger zone lands in PL d, category 3, which means dual channel, monitored, with a reset that cannot restart the machine by itself. Everything else — which relay, which contactors, how the feedback loop is wired — follows from that.
The wiring that carries the category
Dual channel means two independent paths from the E-stop contacts to the relay, routed separately, so a single fault cannot defeat both. The feedback loop from the contactors must be in series and must open if a contactor welds. The reset must be a monitored pushbutton inside the guarded area, not a key switch outside it. None of this is expensive; all of it is invisible if the drawing does not show it.
Documenting it
Deliver the safety circuit as a separate drawing sheet with the category marked, the components listed with their safety data, and the proof test interval stated. That single sheet is what a machinery auditor asks for. The PLC and HMI cabinet can be supplied with the safety circuit built to the customer's own risk assessment, and the first article inspection note covers how the circuit is verified before dispatch.