Which Components to Keep in Stock
Stock is cash on a shelf. panel builder holding every possible component ties up working capital and still finds the one part that is missing; a builder holding nothing pays expediting fees every month.
What is worth stocking
Fast movers used on most panels: terminal blocks, DIN rail, ferrules, wire in the common sizes, standard contactors and relays, MCBs in the common ratings, 24 V supplies under 5 A. These are cheap per unit and their absence stops a build.
What should not be stocked
Drives, PLC CPUs and touch panels — model-specific, expensive, and superseded every two years. Main breakers above 250 A. Anything a customer has nominated by name, because the next customer will nominate something else.
The rule
Stock what is used on more than half the panels and costs less than a few hundred dollars. Order everything else per project, with the lead time quoted honestly. Review the stock list twice a year against actual consumption, because a list that is never reviewed slowly fills with parts nobody uses. The lead time note explains why stock decisions change delivery dates, and the spare parts note covers the customer's side of the same question.