Counterfeit breakers and damaged drives are found in ten minutes of goods-in inspection or in the first week of production. The ten minutes are cheaper.

What to check on arrival

Packaging integrity and date codes, then the product itself: moulding quality, terminal finish, the presence of a serial number and its format, and whether the marking matches the datasheet. Counterfeit breakers often have a correct front label and a lighter body with thinner terminal plating.

Function, not just appearance

Sample-test one unit per batch: trip a breaker with a test current, check a contactor's coil resistance, power up a drive and confirm it reads the expected firmware. On high-value items, register the serial number with the manufacturer — most now offer verification, and it takes a minute.

Recording

Log the batch, supplier, date and result. When a component fails in a panel two years later, that log is what identifies the affected panels. The traceability note covers the panel side, and the custom control panel is built only from components that passed goods-in inspection with a recorded batch number.