Cut-Out Tolerance for Meters and HMI
Cut-outs for meters, displays and pushbuttons are made on a laser and then painted. Each step moves the edge, and 2 mm at the end is the difference between a sealed instrument and a visible gap.
Where the tolerance goes
Laser cutting holds ±0.2 mm. Powder coating adds 60 to 100 µm per face, so a rectangular opening shrinks by 0.12 to 0.2 mm overall. Bending of the door panel can move a cut-out by another 0.3 mm if the bend line is near it. Total variation is under 0.5 mm, which is fine for a device with a 1 mm bezel overlap and not fine for one with a 0.5 mm overlap.
Drawing practice
Dimension the cut-out to the device manufacturer's drawing, not to the device size. State the tolerance and the finish. Where the overlap is tight, mask the opening before coating so the edge stays bare — the gasket seals on metal, not on powder.
Verification
Check the first door of a batch with the actual instrument before the rest are cut. gauge block or a sample device on the bench catches the error while the sheet is still flat. The HMI mounting note covers the display case, and the custom control panel is built from the device datasheets supplied with the order.